ADS131M02
Key datasheet specifications and the closest alternatives, ranked by parametric similarity and grounded in the manufacturer datasheet.
This Texas Instruments datasheet covers the ADS131M02, a 2-channel, simultaneously-sampling, 24-bit delta-sigma ADC designed for energy metering and power metrology. Key features include a dynamic range of 102 dB at 4 kSPS, programmable data rates up to 64 kSPS, and gains from 1 to 128. The device offers high-impedance inputs for direct sensor connection, integrated channel-to-channel phase calibration, and an internal 1.2-V reference. It supports current-detect mode for tamper detection and operates over an industrial temperature range of -40°C to +125°C in a 20-pin package.
Datasheet parameters
| Parameter | Min | Typ | Max | Conditions |
|---|---|---|---|---|
| quiescent current | — | 1.8 mA | 2.15 mA | High-resolution mode |
| supply voltage range | 1.65 V | — | 3.6 V | |
| input offset voltage drift | — | 300 nV/°C | — | |
| cmrr | — | 100 dB | — | At dc |
| operating temperature | -40 °C | — | 125 °C | |
| clock frequency | 300 kHz | 8.19 MHz | 8.4 MHz | High-resolution mode |
| power dissipation | — | 6.2 mW | — | High-resolution mode |
| input bias current | — | 600 nA | — | Gain = 1, 2, or 4, VINP = VINN = 0 V, IB = (IBP+ IBN) / 2 |
| propagation delay | — | — | 50 ns | |
| psrr | — | 75 dB | — | AVDD at dc |
| adc resolution | — | 24 bit | — | |
| operate time | — | 250 µs | — | Measured from supplies at 90% to first\overline{DRDY}rising edge |
| sample rate | 250 Hz | — | 64 kHz | |
| settling time | — | 323 µs | — | |
| channel count | — | 2 | — |
Closest matches to ADS131M02
Frequently asked questions
What is the ADC resolution of the ADS131M02?
The ADC resolution is 24 bit.
What is the channel count of the ADS131M02?
The channel count is 2.
What is the clock frequency in High-resolution mode?
The clock frequency is 8.19 MHz in High-resolution mode.
What is the CMRR of the ADS131M02 at dc?
The CMRR is 100 dB at dc.
What is the input bias current when the gain is 1, 2, or 4, VINP = VINN = 0 V, and IB = (IBP+ IBN) / 2?
The input bias current is 600 nA.
What is the input offset voltage drift of the ADS131M02?
The input offset voltage drift is 300 nV/°C.
What is the operate time of the ADS131M02?
The operate time is 250 µs, measured from supplies at 90% to first DRDY rising edge.
What is the maximum operating temperature for the ADS131M02?
The maximum operating temperature is 125 °C.