What the LTR-308ALS does
The LTR-308ALS-01 is an integrated low voltage I2C ambient light sensor in a 2x2mm chipled lead-free surface mount package. It operates from 1.7V to 3.6V across temperatures of -40 to +85 ºC. The device offers 16 to 20 bits effective resolution with a wide dynamic range from 0.01 to 157K lux. It features a built-in temperature compensation circuit and a programmable interrupt function with hysteresis. The sensor provides automatic rejection for 50Hz/60Hz lighting flicker and maintains a close to human eye spectral response. It is typically used to control display panel brightness in mobile, computing, and consumer devices.
Datasheet parameters
| Parameter | Min | Typ | Max | Conditions | Source |
|---|---|---|---|---|---|
| quiescent current | — | 110 µA | — | Max. duty cycle, Vdd = 1.8V, Gain 3x | Lite-On datasheet, p. 6 — 4.3. Electrical Specifications (VDD = 1.8V, Ta=25°C, unless otherwise… |
| supply voltage range | 1.7 V | — | 3.6 V | Lite-On datasheet, p. 6 — 4.2. Recommended Operating Conditions | |
| operating temperature | -40 °C | — | 85 °C | Lite-On datasheet, p. 6 — 4.2. Recommended Operating Conditions | |
| standby current | — | 1 µA | — | Shutdown Mode | Lite-On datasheet, p. 6 — 4.3. Electrical Specifications (VDD = 1.8V, Ta=25°C, unless otherwise… |
| sample rate | — | 10 Hz | — | Default ALS Measurement Rate = 100 ms; programmable 25 ms to 2000 ms (bits 2:0 of ALSMEAS RATE register 0x04) | Lite-On datasheet, p. 12 — ALS_MEAS_RATE Register (0x04) (Read/Write) |
Closest matches to LTR-308ALS
Frequently asked questions
What is the maximum operating temperature for the LTR-308ALS-01?
The maximum operating temperature is 85 °C.
What is the maximum quiescent current under Max. duty cycle, Vdd = 1.8V, Gain 3x conditions?
The maximum quiescent current is 110 µA.
What is the default sample rate for the LTR-308ALS-01?
The default sample rate is 10 Hz.
What is the standby current in Shutdown Mode?
The standby current is 1 µA.
What is the supply voltage range for the LTR-308ALS-01?
The supply voltage range is 3.6 V.