TMP112
Every spec below is cited to the manufacturer datasheet. Compare the closest alternatives, then ask the assistant what it means for your design.
What the TMP112 does
The TMP112 is a two-wire, serial output temperature sensor in an SOT-563 package. It features a 12-bit resolution with 0.0625°C steps and operates on a 1.4V to 3.6V supply. The device offers an accuracy of ±0.5°C from 0°C to +65°C and supports SMBus and two-wire interfaces. It is designed for portable, battery-powered, and industrial applications requiring precise temperature monitoring, such as in computers, medical instruments, and motor control systems. The TMP112 runs on as little as 10μA during operation and 1μA in shutdown mode.
Datasheet parameters
| Parameter | Min | Typ | Max | Conditions | Source |
|---|---|---|---|---|---|
| quiescent current | — | 7 µA | — | 串行总线未激活, CR1 = 0, CR0 = 0 (默认值) | TI datasheet, p. 3 — 电气特性 |
| supply voltage range | 1.4 V | — | 3.6 V | TI datasheet, p. 3 | |
| operating temperature | -40 °C | — | 125 °C | TI datasheet, p. 3 — 电气特性 | |
| standby current | — | 500 nA | — | SD 位 = '1' 关断模式 | TI datasheet, p. 9 |
| rise time | — | — | 300 ns | 时钟/数据上升时间 | TI datasheet, p. 13 — 表 14. 时序图定义 |
| fall time | — | — | 300 ns | 时钟/数据下降时间 | TI datasheet, p. 13 — 表 14. 时序图定义 |
| sample rate | — | 4 Hz | — | 默认值 (CR1 = 1, CR0 = 0) | TI datasheet, p. 9 — 表 9. 转换率设置 |
Closest matches to TMP112
Frequently asked questions
What is the fall time (tf) for the TMP112?
The fall time (tf) is 300 ns.
What is the maximum operating temperature for the TMP112?
The operating temperature is 125 °C.
What is the rise time (tr) for the TMP112?
The rise time (tr) is 300 ns.
What is the default sample rate when CR1 = 1 and CR0 = 0?
The default sample rate is 4 Hz when CR1 = 1 and CR0 = 0.
What is the standby current when the SD bit is '1' (shutdown mode)?
The standby current is 500 nA when the SD bit is '1' (shutdown mode).
What is the supply voltage range for the TMP112?
The supply voltage range is 3.6 V.