The LSM6DSV is a 6-axis inertial measurement unit combining a 3-axis digital accelerometer and a 3-axis digital gyroscope with embedded sensor fusion. It features a triple-channel architecture supporting user interface, optical image stabilization, and electronic image stabilization data processing. The device operates with an analog supply voltage of 1.71 V to 3.6 V and consumes 0.65 mA in combo high-performance mode. It offers full-scale ranges from ±2 to ±16 g and ±125 to ±4000 dps. Typically used for motion tracking, gesture detection, augmented reality, wearables, and camera stabilization, the LSM6DSV includes a smart FIFO up to 4.5 KB and supports SPI, I²C, and MIPI I3C interfaces.

Next step
Start building with LSM6DSV → Every number above is cited straight from the datasheet — ask what they mean for your design, and the assistant answers from the same source documents.
01 — Key specifications

Datasheet parameters

Datasheet parameters for LSM6DSV
ParameterMinTypMaxConditionsSource
quiescent current — 2.6 µA — power-down (IddPD) ST datasheet, p. 13 — Table 4. Electrical characteristics
supply voltage range 1.71 V 1.8 V 3.6 V ST datasheet, p. 13 — Table 4. Electrical characteristics
standby current — 2.6 µA — ST datasheet, p. 13 — Table 4. Electrical characteristics
output voltage low — — 200 mV IOL = 4 mA(2) ST datasheet, p. 13 — Table 4. Electrical characteristics
02 — Alternatives

Closest matches to LSM6DSV

LSM6DS3TR-C 1.2× higher quiescent current, 1.2× higher standby current, similar operating temperature
MPU-6000 1.9× higher quiescent current, 1.6× higher supply voltage range, similar operating temperature
ICM-42607-C 2.0× lower output voltage low, similar operating temperature, similar supply voltage range
TSL2560 5.4× higher sample rate, 1.7× higher supply voltage range, 1.1× lower operating temperature
LIS2DH12 5.2× lower standby current, 4.2× higher quiescent current, 1.4× higher supply voltage range
LIS3DH 5.2× lower standby current, 4.2× higher quiescent current, 1.4× higher supply voltage range
LTR-308ALS-01 5.3× higher sample rate, 2.6× lower standby current, 1.5× higher supply voltage range
ADXL345-EP 1.4× higher supply voltage range, 1.1× higher operating temperature
03 — FAQ

Frequently asked questions

What is the maximum output voltage low (vol) when IOL = 4 mA?

The output voltage low is 200 mV.

What is the standby current of the LSM6DSV?

The standby current is 2.6 µA.

What is the supply voltage range for the LSM6DSV under the vdd condition in the Electrical characteristics?

The supply voltage range is 1.8 V.