ISO7240C
Every spec below is cited to the manufacturer datasheet. Compare the closest alternatives, then ask the assistant what it means for your design.
What the ISO7240C does
The ISO7240, ISO7241, and ISO7242 are quad-channel digital isolators with logic input and output buffers separated by a silicon dioxide barrier. The family spans 25-Mbps and 150-Mbps signaling rates, operating from 2.8-V, 3.3-V, or 5-V supplies with a –40°C to 125°C range. Variants include TTL input thresholds with noise filtering (C) or CMOS thresholds without filtering (M), plus a failsafe-output option (CF). These devices block high voltage, isolate grounds, and prevent noise currents in industrial fieldbus, computer peripheral, servo control, and data acquisition applications.
Datasheet parameters
| Parameter | Min | Typ | Max | Conditions | Source |
|---|---|---|---|---|---|
| quiescent current | — | 1 mA | — | ICC1, Vcc1 = Vcc2 = 5 V, VI = VCC or 0 V, all channels no load, EN at 3 V | TI datasheet, p. 4 — IEC 60747-5-2 INSULATION CHARACTERISTICS |
| output current | — | — | 4 mA | TI datasheet, p. 3 — RECOMMENDED OPERATING CONDITIONS | |
| supply voltage range | 3.15 V | — | 5.5 V | ISO7240C/CF, ISO7242C, ISO724xM, | TI datasheet, p. 3 — RECOMMENDED OPERATING CONDITIONS |
| abs max current (abs max) | — | — | 239 mA | SOIC-8 | TI datasheet, p. 18 — IEC SAFETY LIMITING VALUES |
| operating temperature | -40 °C | — | 125 °C | TI datasheet, p. 1 | |
| power dissipation | — | — | 220 mW | VCC1 = VCC2 = 5.5 V, TJ = 150°C, CL = 15 pF, Input a 50% duty cycle square wave | TI datasheet, p. 18 — THERMAL CHARACTERISTICS |
| input capacitance | — | 2 pF | — | INat VCC, VI = 0.4 sin (4E6πt) | TI datasheet, p. 8 — over recommended operating conditions (unless otherwise noted) |
| isolation voltage | — | — | 560 V | TI datasheet, p. 3 — over recommended operating conditions (unless otherwise noted) | |
| propagation delay | — | 15 ns | 20 ns | See Figure 2 | TI datasheet, p. 11 — over recommended operating conditions (unless otherwise noted) |
| data rate | — | 25 Mbps | — | TI datasheet, p. 2 — AVAILABLE OPTIONS | |
| rise time | — | 2 ns | — | See Figure 1 | TI datasheet, p. 11 — over recommended operating conditions (unless otherwise noted) |
| fall time | — | 2 ns | — | TI datasheet, p. 11 — over recommended operating conditions (unless otherwise noted) | |
| output voltage low | — | — | 100 mV | TI datasheet, p. 4 — IEC 60747-5-2 INSULATION CHARACTERISTICS | |
| cmti | 25 GV/s | 50 GV/s | — | TI datasheet, p. 4 — IEC 60747-5-2 INSULATION CHARACTERISTICS | |
| channel count | — | 4 | — | TI datasheet, p. 2 — AVAILABLE OPTIONS |
Closest matches to ISO7240C
Frequently asked questions
What is the channel count of the ISO7240C?
The channel count is 4.
What is the common-mode transient immunity (cmti) specified in the ELECTRICAL CHARACTERISTICS?
The common-mode transient immunity (cmti) is 50 GV/s.
What is the fall time of the ISO7240C under normal operating conditions?
The fall time is 2 ns.
What is the isolation voltage under viorm over recommended operating conditions?
The isolation voltage is 560 V under viorm over recommended operating conditions.
What is the maximum operating temperature for the ISO7240C?
The maximum operating temperature is 125 °C.
What is the output current (iol) under RECOMMENDED OPERATING CONDITIONS?
The output current (iol) is 4 mA under RECOMMENDED OPERATING CONDITIONS.
What is the output voltage low (VOL) specified in the ELECTRICAL CHARACTERISTICS?
The output voltage low (VOL) is 100 mV.
What is the power dissipation under the conditions VCC1 = VCC2 = 5.5 V, TJ = 150°C, CL = 15 pF, and Input a 50% duty cycle square wave?
The power dissipation is 220 mW.
What is the propagation delay of the ISO7240C under normal operating conditions as shown in Figure 2?
The propagation delay is 15 ns.