sensors

TMP36

Every spec below is cited to the manufacturer datasheet. Pick your exact ordering code, compare the closest alternatives, then ask the assistant what it means for your design.

00 — Overview

What the TMP36 family does

The TMP35/TMP36/TMP37 are low voltage, precision centigrade temperature sensors that provide a voltage output linearly proportional to Celsius temperature. These devices operate from a single 2.7 V to 5.5 V supply with quiescent current below 50 µA and a shutdown current under 0.5 µA. The TMP36 specifically offers ±2°C accuracy over the -40°C to +125°C range with a 10 mV/°C scale factor and 750 mV output at 25°C. They simplify interfacing to A/D converters and are typically used in environmental control, thermal protection, industrial process control, fire alarms, power system monitors, and CPU thermal management. Available in TO-92, SOIC-8, and SOT-23 packages, they require no external calibration.

Next step
Start building with TMP36 → Every number above is cited straight from the datasheet — ask what they mean for your design, and the assistant answers from the same source documents.
01 — Key specifications

TMP36 datasheet parameters

ParameterMinTypMaxConditionsSource
quiescent current 50 µA Unloaded; (on) ADI datasheet, p. 4 — Table 1.
output voltage 250 mV TA = 25°C; tmp35 ADI datasheet, p. 4 — Table 1.
output current 0 A 50 µA ADI datasheet, p. 4 — Table 1.
supply voltage range 400 mV VS = 5.5 V ADI datasheet, p. 4 — Table 1.
operating temperature -40 °C 125 °C ADI datasheet, p. 3
standby current 500 nA ADI datasheet, p. 3
03 — Alternatives

Closest matches to TMP36

TC1047 4.0× higher output current, 3.0× higher output voltage, 2.0× higher supply voltage range
MAX31820 1.9× higher supply voltage range, 1.5× higher standby current, 1.2× lower operating temperature
MAX31820MCR+ 1.9× higher supply voltage range, 1.5× higher standby current, 1.2× lower operating temperature
TMP112 1.4× higher supply voltage range, similar operating temperature, similar standby current
BME280 2.5× lower standby current, 1.7× lower operating temperature, similar supply voltage range
DS18B20 2.2× higher supply voltage range, 1.5× higher standby current, 1.2× lower operating temperature
ICM-42607-C 11.0× higher quiescent current, 1.9× lower operating temperature, similar supply voltage range
MAX31865 1.8× higher supply voltage range, similar operating temperature
Design help What do I need around the TMP36? →