What the SPX5205 family does
The SPX5205 is a 150mA, low-noise LDO voltage regulator available in fixed output voltages of 1.2V through 5.0V and an adjustable version within a 5-pin SOT-23 package. Key specifications include 40μV RMS output noise, 70μA quiescent current, and a dropout voltage of 210mV at 150mA. This regulator is typically used in battery-powered systems, portable consumer equipment, cellular phones, and radio control systems where power conservation is desired.
SPX5205 datasheet parameters
| Parameter | Min | Typ | Max | Conditions | Source |
|---|---|---|---|---|---|
| quiescent current | — | 70 µA | — | IGND, IL = 100 uA, typ | Exar datasheet, p. 2 — ELECTRICAL CHARACTERISTICS |
| output voltage | — | 1.2 V | — | Exar datasheet, p. 8 — ORDERING INFORMATION | |
| output current | — | 150 mA | — | Exar datasheet, p. 2 — ELECTRICAL CHARACTERISTICS | |
| operating temperature | -40 °C | — | 125 °C | Exar datasheet, p. 2 — RECOMMENDED OPERATING CONDITIONS | |
| standby current | — | 50 nA | — | VENABLE <= 0.4 V, typ | Exar datasheet, p. 2 — ELECTRICAL CHARACTERISTICS |
| psrr | — | 70 dB | — | Exar datasheet, p. 2 — ELECTRICAL CHARACTERISTICS | |
| dropout voltage | — | 210 mV | — | IL = 150 mA, typ | Exar datasheet, p. 2 — ELECTRICAL CHARACTERISTICS |
| output noise voltage | — | 300 µV | — | IL = 10 mA, CL = 1 uF, CIN = 1 uF, 10 Hz-100 kHz, typ | Exar datasheet, p. 2 — ELECTRICAL CHARACTERISTICS |
| output count | — | 1 | — | Exar datasheet, p. 2 — ELECTRICAL CHARACTERISTICS |
SPX5205 frequently asked questions
What is the typical dropout voltage when IL = 150 mA?
The typical dropout voltage is 210 mV.
What is the maximum operating temperature for the SPX5205?
The operating temperature is 125 °C.
What is the output count of the SPX5205?
The output count is 1.
What is the output current of the SPX5205?
The output current is 150 mA.
What is the typical output noise voltage when IL = 10 mA, CL = 1 uF, CIN = 1 uF, and the frequency range is 10 Hz-100 kHz?
The typical output noise voltage is 300 µV.
What is the output voltage of the SPX5205?
The output voltage is 1.2 V.
What is the typical quiescent current (IGND) when the load current (IL) is 100 uA?
The typical quiescent current is 70 µA.
What is the typical standby current when VENABLE is less than or equal to 0.4 V?
The typical standby current is 50 nA when VENABLE <= 0.4 V.