SS49E
Every spec below is cited to the manufacturer datasheet. Pick your exact ordering code, compare the closest alternatives, then ask the assistant what it means for your design.
What the SS49E family does
The SS39ET/SS49E/SS59ET Series are linear Hall-effect sensor ICs available in SOT-23, Flat TO-92-style, and SOT-89B packages. They operate on a supply voltage of 2.7 Vdc to 6.5 Vdc with a typical current consumption of 6 mA at 5 Vdc. These devices feature a sensitivity of 1.0 to 1.75 mV/Gauss and an operating temperature range of -40 °C to 100 °C. They are typically used for basic current sensing, anti-tampering detection, position sensing in e-bikes, magnetic code reading, and speed adjustment triggers in various industrial and medical applications.
Next step
Start building with SS49E →
Every number above is cited straight from the datasheet — ask what they mean for your design, and the assistant answers from the same source documents.
Ordering code:
SS39ET datasheet parameters
| Parameter | Min | Typ | Max | Conditions | Source |
|---|---|---|---|---|---|
| quiescent current | — | 6 mA | 10 mA | 25 °C [77 °F] | Honeywell datasheet, p. 3 — Table 1. Operating Characteristics (Vs = 5.0 V, Ta = -40 °C to 85 °… |
| output current | 1 mA | 1.5 mA | 1.5 mA | Vs > 3.0 V | Honeywell datasheet, p. 3 — Table 1. Operating Characteristics (Vs = 5.0 V, Ta = -40 °C to 85 °… |
| supply voltage range | 2.7 V | — | 6.5 V | — | Honeywell datasheet, p. 3 — Table 1. Operating Characteristics (Vs = 5.0 V, Ta = -40 °C to 85 °… |
| operating temperature | -40 °C | — | 100 °C | Honeywell datasheet, p. 3 — Table 1. Operating Characteristics (Vs = 5.0 V, Ta = -40 °C to 85 °… |
SS49E datasheet parameters
| Parameter | Min | Typ | Max | Conditions | Source |
|---|---|---|---|---|---|
| quiescent current | — | 6 mA | 10 mA | 25 °C [77 °F] | Honeywell datasheet, p. 3 — Table 1. Operating Characteristics (Vs = 5.0 V, Ta = -40 °C to 85 °… |
| output current | 1 mA | 1.5 mA | 1.5 mA | Vs > 3.0 V | Honeywell datasheet, p. 3 — Table 1. Operating Characteristics (Vs = 5.0 V, Ta = -40 °C to 85 °… |
| supply voltage range | 2.7 V | — | 6.5 V | — | Honeywell datasheet, p. 3 — Table 1. Operating Characteristics (Vs = 5.0 V, Ta = -40 °C to 85 °… |
| operating temperature | -40 °C | — | 100 °C | Honeywell datasheet, p. 3 — Table 1. Operating Characteristics (Vs = 5.0 V, Ta = -40 °C to 85 °… |
SS59ET datasheet parameters
| Parameter | Min | Typ | Max | Conditions | Source |
|---|---|---|---|---|---|
| quiescent current | — | 6 mA | 10 mA | 25 °C [77 °F] | Honeywell datasheet, p. 3 — Table 1. Operating Characteristics (Vs = 5.0 V, Ta = -40 °C to 85 °… |
| output current | 1 mA | 1.5 mA | 1.5 mA | Vs > 3.0 V | Honeywell datasheet, p. 3 — Table 1. Operating Characteristics (Vs = 5.0 V, Ta = -40 °C to 85 °… |
| supply voltage range | 2.7 V | — | 6.5 V | — | Honeywell datasheet, p. 3 — Table 1. Operating Characteristics (Vs = 5.0 V, Ta = -40 °C to 85 °… |
| operating temperature | -40 °C | — | 100 °C | Honeywell datasheet, p. 3 — Table 1. Operating Characteristics (Vs = 5.0 V, Ta = -40 °C to 85 °… |
Closest matches to SS49E
AH49E
6.7× higher output current, 1.7× lower quiescent current, 1.3× lower operating temperature
DRV5055
1.4× higher operating temperature, 1.4× lower supply voltage range, similar quiescent current
GH1248
3.3× higher output current, 1.5× lower supply voltage range, 1.3× lower operating temperature
MT9101
1.8× higher operating temperature, 1.1× higher quiescent current, 1.1× lower supply voltage range
CC6103
3.0× lower quiescent current, 1.8× higher operating temperature, 1.1× lower supply voltage range
HAL2041
3.3× higher output current, 1.8× higher operating temperature, 1.2× lower supply voltage range
HAL248G
6.7× higher output current, 1.4× higher operating temperature, 1.3× lower supply voltage range
HAL3144E
3.7× higher supply voltage range, 1.8× higher operating temperature, 1.2× lower quiescent current
Design help