SN54HC595
Every spec below is cited to the manufacturer datasheet. Compare the closest alternatives, then ask the assistant what it means for your design.
What the SN54HC595 does
The SN54HC595/SN74HC595 are 8-bit shift registers with 3-state output registers operating from 2 V to 6 V. They feature a typical propagation delay of 13 ns, low input current of 1 μA, and output drive of ±6 mA at 5 V. These devices typically serve in network switches, power infrastructure, LED displays, and servers. The family includes variants in LCCC, CDIP, PDIP, SOIC, SSOP, and TSSOP packages.
Datasheet parameters
| Parameter | Min | Typ | Max | Conditions | Source |
|---|---|---|---|---|---|
| quiescent current | — | 160 µA | — | VI = VCCor 0, IO = 0; 6 V; MAX = 8 | TI datasheet, p. 5 — over recommended operating free-air temperature range (unless otherwise no… |
| output current (abs max) | — | — | 35 mA | VO = 0 to VCC | TI datasheet, p. 4 — 6.1 Absolute Maximum Ratings |
| supply voltage range | 2 V | 5 V | 6 V | TI datasheet, p. 4 — 6.3 Recommended Operating Conditions | |
| operating temperature | -55 °C | — | 125 °C | TI datasheet, p. 4 — 6.3 Recommended Operating Conditions | |
| clock frequency | — | — | 6 MHz | 2 V; MAX = 5 | TI datasheet, p. 6 — over operating free-air temperature range (unless otherwise noted) |
| output voltage high | — | — | 1.9 V | VI = VIHor VIL; IOH = -20 μA; 2 V; TA = _25°C; 1.9; TYP = 1.998 | TI datasheet, p. 5 — over recommended operating free-air temperature range (unless otherwise no… |
| output voltage low | — | 100 mV | — | VI = VIHor VIL; IOL = 20 μA; 2 V; TYP = 0.002; MAX = 0.1 | TI datasheet, p. 5 — over recommended operating free-air temperature range (unless otherwise no… |
Closest matches to SN54HC595
Frequently asked questions
What is the maximum clock frequency (fclock) at 2 V over the operating free-air temperature range?
The maximum clock frequency is 6 MHz at 2 V over the operating free-air temperature range.
What is the maximum operating temperature (ta) according to 6.3 Recommended Operating Conditions?
The maximum operating temperature (ta) is 125 °C.
What is the absolute maximum output current (io) when VO = 0 to VCC?
The absolute maximum output current is 35 mA.
What is the output voltage high (VOH) when VI = VIH or VIL, IOH = -20 μA, VCC = 2 V, and TA = 25°C?
The output voltage high is 1.9 V.
What is the maximum output voltage low (vol) when VI = VIH or VIL, IOL = 20 μA, and the supply voltage is 2 V?
The maximum output voltage low is 100 mV.
What is the maximum quiescent current when VI = VCC or 0, IO = 0, at 6 V, with 8 ICs, over the recommended operating free-air temperature range?
The maximum quiescent current is 160 µA.
What is the supply voltage range for the SN54HC595 under vcc conditions?
The supply voltage range is 5 V.