LM358B
Every spec below is cited to the manufacturer datasheet. Compare the closest alternatives, then ask the assistant what it means for your design.
What the LM358B does
The LM158/LM258/LM358/LM2904 family are industry-standard dual operational amplifiers available in commercial, industrial, and military temperature grades. They feature a wide supply range of 3V to 36V, 1.2MHz unity-gain bandwidth, and 300µA quiescent current per channel. These devices are typically used in merchant network power supplies, motor control systems, and uninterruptible power supplies. The B and BA versions offer enhanced stability with lower offset voltage and integrated EMI filters for rugged applications.
Datasheet parameters
| Parameter | Min | Typ | Max | Conditions | Source |
|---|---|---|---|---|---|
| quiescent current | — | 300 µA | 460 µA | VS = 5 V; IO = 0 A; TA = -40°C to +125°C | TI datasheet, p. 9 |
| output current | 60 µA | 100 µA | — | VID = -1 V; VO = (V-) + 200 mV | TI datasheet, p. 6 — 5.5 Electrical Characteristics: LM358B and LM358BA |
| supply voltage range | 3 V | — | 36 V | LM358B, LM358BA, LM2904B, LM2904BA | TI datasheet, p. 5 — over operating ambient temperature range (unless otherwise noted) |
| abs max voltage (abs max) | -26 V | — | 26 V | TI datasheet, p. 4 — 5.1 Absolute Maximum Ratings | |
| input offset voltage drift | — | 3.5 µV/°C | 11 µV/°C | TA = -40°C to +85°C(1) | TI datasheet, p. 6 — 5.5 Electrical Characteristics: LM358B and LM358BA |
| input offset voltage | — | 300 µV | 3 mV | LM358B | TI datasheet, p. 6 — 5.5 Electrical Characteristics: LM358B and LM358BA |
| gain bandwidth | — | 1.2 MHz | — | TI datasheet, p. 6 — 5.5 Electrical Characteristics: LM358B and LM358BA | |
| operating temperature | -40 °C | — | 85 °C | LM358B, LM358BA | TI datasheet, p. 5 — over operating ambient temperature range (unless otherwise noted) |
| input offset current drift | — | 10 pA/°C | — | TA = -40°C to +85°C | TI datasheet, p. 6 — 5.5 Electrical Characteristics: LM358B and LM358BA |
| input offset current | — | — | 5 nA | TA = -40°C to +85°C(1) | TI datasheet, p. 6 — 5.5 Electrical Characteristics: LM358B and LM358BA |
| input bias current | — | — | -50 nA | TA = -40°C to +85°C(1) | TI datasheet, p. 6 — 5.5 Electrical Characteristics: LM358B and LM358BA |
| slew rate | — | 0.5 V/µs | — | G = +1 | TI datasheet, p. 6 — 5.5 Electrical Characteristics: LM358B and LM358BA |
| input voltage noise density | — | 40 nV/√Hz | — | f = 1 kHz | TI datasheet, p. 6 — 5.5 Electrical Characteristics: LM358B and LM358BA |
| settling time | — | 4 µs | — | To 0.1%, VS = 5 V, 2-V step, G = +1, CL = 100 pF | TI datasheet, p. 6 — 5.5 Electrical Characteristics: LM358B and LM358BA |
Closest matches to LM358B
Frequently asked questions
What is the absolute maximum voltage rating for the LM358B?
The absolute maximum voltage is 26 V.
What is the input offset voltage drift for the LM358B when the temperature is between -40°C and +85°C?
The input offset voltage drift is 3.5 µV/°C.
What is the input voltage noise density of the LM358B at f = 1 kHz?
The input voltage noise density is 40 nV/√Hz at f = 1 kHz.
What is the operating temperature for the LM358B and LM358BA at ta over the operating ambient temperature range (unless otherwise noted)?
The operating temperature is 85 °C.
What is the settling time of the LM358B to 0.1% under the conditions of VS = 5 V, a 2-V step, G = +1, and CL = 100 pF?
The settling time is 4 µs.